English: Explanation of Tensairity girder as structural component.
Comparison of (a) a normal steel frameworkgirder and (b) a tensairity girder. When the load applies from the top directing downward (trying to bend the girder), force acts on upper rods of girders as compression stress yet as tension stress on lower parts. This stress tends to decrease girder width making it less rigid. (A girder of zero width has zero flexural strength.) To prevent this upper and lower rods must be separated. Classical framework girders ensure this using triangular space frames. In the tensairity girder strong airbags pressurized with a gas is used instead. The pure tension on the lower rod load may be replaced by rope or the strong airbag membrane itself. This results in a much better strength-to-weight ratio.
de partager – de copier, distribuer et transmettre cette œuvre
d’adapter – de modifier cette œuvre
Sous les conditions suivantes :
paternité – Vous devez donner les informations appropriées concernant l'auteur, fournir un lien vers la licence et indiquer si des modifications ont été faites. Vous pouvez faire cela par tout moyen raisonnable, mais en aucune façon suggérant que l’auteur vous soutient ou approuve l’utilisation que vous en faites.